Pure Appl. Chem., 1986, Vol. 58, No. 3, pp. 469-479
http://dx.doi.org/10.1351/pac198658030469
ANALYTICAL CHEMISTRY DIVISION
COMMISSION ON ELECTROANALYTICAL CHEMISTRY
Definition and determination of response time of ion selective electrodes
CrossRef Cited-by Linking
- Hattori Toshiaki, Yoshitomo Masaki, Mori Satoshi, Miyamoto Daichi, Kato Ryo, Sawada Kazuaki: CCD-Type Sodium Ion Image Sensor: Dynamic Observation of Ion-Exchange Reactions of a Single Na-Type Cation-Exchange Resin Bead. Electroanalysis (N Y ) 2012, 24, 114. <http://dx.doi.org/10.1002/elan.201100442>
- Yari Abdollah, Sepahvand Reza: Highly sensitive carbon paste electrode with silver-filled carbon nanotubes as a sensing element for determination of free cyanide ion in aqueous solutions. Microchim Acta 2011, 174, 321. <http://dx.doi.org/10.1007/s00604-011-0629-9>
- Yari Abdollah, Papi Fatemeh: Ultra trace mercury(II) detection by a highly selective new optical sensor. Actuat B 2011, 160, 698. <http://dx.doi.org/10.1016/j.snb.2011.08.051>
- Yari Abdollah, Papi Fatemeh: Highly selective sensing of mercury (II) by development and characterization of a PVC-based optical sensor. Actuat B 2009, 138, 467. <http://dx.doi.org/10.1016/j.snb.2009.02.011>
- Thévenot Daniel R., Toth Klara, Durst Richard A., Wilson George S.: Electrochemical biosensors: recommended definitions and classification1International Union of Pure and Applied Chemistry: Physical Chemistry Division, Commission I.7 (Biophysical Chemistry); Analytical Chemistry Division, Commission V.5 (Electroanalytical Chemistry).1. Biosensors bioelectronics 2001, 16, 121. <http://dx.doi.org/10.1016/S0956-5663(01)00115-4>
- Thévenot Daniel R., Toth Klara, Durst Richard A., Wilson George S.: ELECTROCHEMICAL BIOSENSORS: RECOMMENDED DEFINITIONS AND CLASSIFICATION*. Anal Lett 2001, 34, 635. <http://dx.doi.org/10.1081/AL-100103209>
- Ito Takashi, Goto Chihiro: ION-SELECTIVE SOLVENT POLYMERIC MEMBRANE ELECTRODES BASED ON 1-PHENYL-3-METHYL-4-ACYL-5-PYRAZOLONES FOR TRIVALENT LANTHANOID IONS. J Trace Microprobe Techn 2001, 19, 601. <http://dx.doi.org/10.1081/TMA-100107595>
- ITO Takashi, RADECKA Hanna, UMEZAWA Kayoko, KIMURA Tatsuji, YASHIRO Akiko, LIN Xiao Ming, KATAOKA Masamitsu, KIMURA Eiichi, SESSLER Jonathan L., ODASHIMA Kazunori: A Variety of Lipophilic Amines Incorporated in Liquid Membranes Exhibit Potentiometric Responses to Neutral Phenols. Anal Sci 1998, 14, 89. <http://dx.doi.org/10.2116/analsci.14.89>
- Wang Xue D., Shen Wei, Cattrall Robert W., Nyberg Graeme L., Liesegang John: An extrapolation method for the fast evaluation of the fluoride ion-selective electrode equilibrium potential in continuous flow analysis. Electroanalysis (N Y ) 1995, 7, 221. <http://dx.doi.org/10.1002/elan.1140070304>
- Attari M., Fabry P., Quezel G., Mallie´ H.: Models and methods of determining the transient response of ion sensors: comparison with impedance spectroscopy. Actuat B 1995, 25, 737. <http://dx.doi.org/10.1016/0925-4005(95)85163-1>
- Naganawa Ryuichi, Radecka Hanna, Kataoka Masamitsu, Tohda Koji, Odashima Kazunori, Umezawa Yoshio, Kimura Eiichi, Koike Tohru: Potentiometric discrimination between planar and octahedral anionic metal cyano complexes by liquid membrane electrodes based on lipophilic macrocyclic dioxopolyamines. Electroanalysis (N Y ) 1993, 5, 731. <http://dx.doi.org/10.1002/elan.1140050905>
- Kataoka Masamitsu, Naganawa Ryuichi, Odashima Kazunori, Umezawa Yoshio, Kimura Eiichi, Koike Tohru: Potentiometric Liquid Membrane Sensors That Discriminate Linear Homologs and Geometrical/Positional Isomers of Dicarboxylates. Anal Lett 1989, 22, 1089. <http://dx.doi.org/10.1080/00032718908051394>
- Berube Thomas R., Buck Richard P.: Anomalies In Theories of Liquid Membrane Time Responses to Activity Steps. Anal Lett 1989, 22, 1221. <http://dx.doi.org/10.1080/00032718908051402>
